We are migrating products from our old website - www.destiny-electronic.com.my
RM29.95 - RM35.95 RM59.90 - RM65.90
Digital Temperature Control Module W3002, Single Zone, (12VDC / 24VDC / 110-240VAC) [22521921-22521923]
Price RM29.95 - RM35.95 RM59.90 - RM65.90
Brand China OEM
Availability In Stock
Operating Voltage
Quantity
Description
Highlight
  • Wide temperature range, -50 - 110ºC
  • 0.1ºC resolution
  • Compact type
  • Easy to use

Operating Voltage, Stock Code

Operating Voltage Stock Code
12 Vdc 22521922
24 Vdc 22521923
110 - 240 Vac 22521921

Digital Temperature Control Module, W3002, 12VDC, 24VDC, 110-240VAC

The temperature control module, available in 3 operating, 12VDC, 24VDC, 110-240VA, has a control range of -50 to 110ºC with an measurement accuracy of 0.2°C.


Features:

  • Wide temperature range, -50 - 110ºC
  • 0.1ºC resolution
  • Compact type
  • Easy to use

 

Tech Specs:

Attribute Value
Package Module
Type Digital
Number of Outputs 1, Single Zone
Temperature Range -50 - 110ºC
Temperature Control Range -50 - 110ºC
Temperature Measurement Accuracy ±0.2ºC
Temperature Control Accuracy ±0.1ºC
Temperature probe NTC10K (B3950) waterproof type, 1 meter length
Operating Voltage 12VDC, 24VDC, 110-220Vac
Output Power 12VDC: 120W
24VDC: 240W
110-240VAC: 1500W
Dimension 60 x 45 x 31mm
Mounting Dimension 73mm

 

 

Module Button Layout:

Module Button Layout:

Parameters Description Setting Range Factory Setting Values
P0 Lower-limit temperature -50-110°C 25°C
P1 Upper-limit temperature -50-110°C 40°C
P2 Temperature offset -10-10°C 0°C
P3 ON time delay 0-10 minutes 0

Setting P0, lower-limit temperature

1) Press Setting Key once, and the display shows P0 parameter.

2) Press Setting Key again to go to Initial Setting Level.

3) Use the Up / Down Key to set values for P0 parameter.

 

Setting P1, upper-limit temperature

1) Press Setting Key once, and the display shows P0 parameter.

2) Use Up / Down Key to change to another parameter, P1.

3) Press Setting Key again to go to Initial Setting Level. 

4) Use the Up / Down Key to set values for P1 parameter.

 

Setting P2, temperature offset

Temperature offset is a feature that lets you adjust the room temperature reading.

This helps if the temperature control module is in a slightly warm or cold spot, or if the room temperature does not match your old thermostat.

Equation: temperature offset = room's actual ambient temperature - temperature measured

 

1) Press Setting Key once, and the display shows P0 parameter.

2) Use Up / Down Key to change to another parameter, P2.

3) Press Setting Key again to go to Initial Setting Level. 

4) Use the Up / Down Key to set values for P2 parameter.

 

Setting P3, ON time delay

ON time delay is generally required for a refrigerator compressor.

1) Press Setting Key once, and the display shows P0 parameter.

2) Use Up / Down Key to change to another parameter, P3.

3) Press Setting Key again to go to Initial Setting Level. 

4) Use the Up / Down Key to set values for P3 parameter.

 

Setting Heater and Cooler:

 

 

Instructions and Wiring Diagram:

1) Connect a power supply and devices to be controlled to the module.

2) Press Setting Key for at least 3 sec to go to Initial Setting Level and the display flashes.

3) Use the Up / Down Key to set values for P0 parameter and wait for at least 5 sec for the module to save the values.

4) Press Setting Key for at least 3 sec to go to Initial Setting Level and the display flashes.

5) Use the Up / Down Key to set values for P1 parameter and wait for at least 5 sec for the module to save the values.

Note: To do a factory reset, press Up and Down Key for at least 5 seconds. The display shows 888 when a factory reset is completed.

 

Troubleshooting:

1) Check the error.

2) Error Code "LLL", the sensor is at open circuit state. Replace the sensor.

3) Error Code "HHH", the sensor is at short circuit state. Replace the sensor.

 

Dimensions:

 

Useful Video:


 

What's in the box

1x temperature control module

1x probe